2. To re-examine an area where nonrelevant indications obscure interpretation, the inspector should:
3. In contact with water-based vehicles, electricity primarily presents a:
4. A permanent-magnet yoke creates which type of field?
5. Evaluation of indications smaller than about 1.5 mm (1/16 in.) is often:
6. When inspecting a weld with a yoke, two examinations are made with the yoke legs oriented:
9. A longitudinal field (coil) is best for detecting discontinuities that are:
10. The stronger a discontinuity's ability to hold magnetic particles, generally the:
11. Half-wave rectified current combined with dry powder is especially effective because it provides:
14. The temperature range over which magnetic particles may be used is set by the:
16. Vision under conditions of dark adaptation (rod-dominated) is known as:
18. When magnetizing tubular parts by direct contact (through the wall), the inside surface field is:
21. Per typical acceptance criteria, a 'linear indication' is one whose length is:
22. The magnetism that remains in a ferromagnetic material after the magnetizing force has been removed is called:
23. A heat-treated part can be demagnetized by heating it above its Curie temperature, but this is usually avoided because it:
24. When using prods, the spacing between prod tips is typically kept between:
27. The recommended amperage range per 25 mm (1 in.) of diameter for circular magnetization using a DC source is generally:
28. Parts with an L/D ratio less than about 2 may need to be magnetized longitudinally by:
29. A 'low fill factor' coil produces a field that, compared to a high fill factor, requires:
30. A portable 220 V supply with a cable wrap provides 3000 ampere-turns. To provide the same ampere-turns, a prewound coil rated 120 V at 6 A would require:
32. Vision under normal levels of illumination (cone-dominated) is known as:
34. The settling test for bath concentration uses a 100 mL pear-shaped centrifuge tube; the recommended settling volume for fluorescent particles is about:
35. Quantitative Quality Indicators (QQIs / artificial flaw shims) are most useful for:
36. Per SNT-TC-1A, the maximum recommended interval between recertifications for Level I and II is:
37. A magnetic field meter (gaussmeter) with a Hall probe measures the:
38. Tangential field strength at the surface for adequate MT is typically in the range of:
40. The reason for using alternating current for surface-crack detection is its:
41. How many ampere-turns are required to longitudinally magnetize a part 406 mm (16 in.) long and 50 mm (2 in.) in diameter using NI = 45000 / (L/D)?
42. The point on the magnetization curve beyond which an increase in magnetizing force produces little increase in flux density is called:
43. The principal source of ultraviolet (UV-A) radiation used for fluorescent inspection is a:
46. A contrast ratio readily perceived by the human eye in normal lighting is about:
48. A well-documented effect of overexposure of human skin to UV radiation is:
50. The peak wavelength of the UV-A radiation used for fluorescent magnetic particle inspection is approximately:
51. The residual method of magnetic particle testing can be used only on materials that have:
53. The minimum visible (white) light intensity required at the surface for examination with visible (color-contrast) particles is:
56. Which discontinuity is inherent to the casting process?
57. Ferritic and martensitic stainless steels, unlike austenitic grades, are:
59. The three basic levels of NDT certification recognized by SNT-TC-1A and CP-189 are:
61. Discontinuities such as fatigue cracks, stress-corrosion cracks, and creep cracks are classified as:
64. Materials with lower permeability (e.g., high-carbon tool steels) that are harder to magnetize are more subject to:
66. The amount of magnetizing current for prods is based on:
67. Which of the following materials CANNOT be inspected by the magnetic particle method?
68. The most important operator-controlled factor for detecting a given discontinuity is correct field:
69. An arc strike on a finished part is considered a discontinuity because it may:
70. Per CP-189, the frequency of the visual (near and color) examination is typically:
71. Per SNT-TC-1A and CP-189, the technical qualification of NDT personnel is documented by training, experience, and:
75. A discontinuity oriented at a small angle to the magnetic field will produce an indication that is:
76. A field indicator (8-direction pie-type device) verifies field direction but does NOT:
77. A limitation of magnetic particle testing compared with penetrant testing is that MT:
80. Carrier fluids for wet particles should have controlled odor, low viscosity, and:
82. Operating power for typical mobile magnetic particle power packs is:
84. Which particle-application technique provides greater sensitivity for locating subsurface (near-surface) discontinuities?
87. Magnetic flux density (induction) is measured in:
88. Which eyewear is recommended for personnel performing fluorescent inspection under UV-A light?
89. The maximum output current of a standard multidirectional (stationary) unit is on the order of: